GS-08S Mobile phone jammer technical parameters
| |
Fan-out |
Blocking frequency |
Average output power |
Channel output power |
CDMA |
851-894MHz |
33dBm |
6dBm/30KHz (min) |
GSM |
925-960MHz |
33dBm |
5dBm/30KHz (min) |
DCS |
1805-1880MHz |
33dBm |
2dBm/30KHz (min) |
Satellite phone |
1525-1559MHz |
33dBm |
2dBm/30KHz (min) |
| 3G |
2110-2170MHz |
33dBm |
2dBm/30KHz (min) |
| Dimension: (width, height, length)290*110*40MMWeight: 2.5KG Shielding radius: 0-70m |
| Products in box include: 1 host, 1 AC-DC power converter, 4 antennas |
| Application: examination rooms, meeting rooms, news conference at the scene, courts, cinemas, |
| libraries, dedicated products, jail, gas stations etc. |
| Function: Block all kind of band GSM, CDMA, DCS, 3G, Satellite phone etc. |
| |
|
|
|
|
Cell phone jammer main Technical Parament Of Controlled Unit
1.Communicate via electrical wire and central controller: single-phase current, band rate is 600bps;
2.Address coding: 1~1024, binary number switch to realize;
3.Control load currentct:≦35A;
4.Load threshold cuttent: 100mA;
5.Power: static 200mW, dynamic(when communicating): 5W
6.Electromagnetic Compatibility: According to IEC 1000-4-2、3、4、5
7.Using environment:
(1).Power supply: 85VAC—250VAC,50Hz/60Hz;
(2).Temperature:-20oC -- +70oC;
(3).Humidity: 95%, do not coaqulate.
Main Technical Parament Of Central Communication Controller
1.Communicate via electrical wire and central controller: three phase alternating current, band rate is 600 bps;
2.Realise controlled units' phase automatically.(R、Y、B)
3. Supply local area network interface, standard RS-232 interface and telephone net interface(Preliminary, not open yet).
Local area network interface: Is already open, as a communication interface of cental communication controller and main control
computer in intelligent mobile phone jammer systemStandard RS-232 interface: Only for manufacturer, manufacture uses it for
built-in IP and get way ect.Telephone net interface: Preliminary, not open yet. In order to realize telephone net remote set central
communication controller's parament in the futhure. Also may use this to send date to upper department. But this is still in
reasearch, So telephone net interace is only for preliminary, not used yet.
4.Can transmit broadcasting instruction at the same time in R, Y, B phase.
5.PC and MODEM built in it.
6.electromagnetic compatibility: According to IEC 1000-4-2、3、4、5
7.Using environmen:
(1).Power supply: 85VAC—250VAC,50Hz/60Hz;
(2).Temperature: -20oC -- +70oC;
(3).Humidity: 95%, do not coaqulate.